Slab edge R.C. consideration

For R.C. design, catiliver span, as moment increased, it requires more reinforcement at the tension side and so is the Tension Lap/ Anchorage Length(TL/AL) of reinforcement increaed from the end until 100%. Under design assumption, full anchorage is required at the critical section of the member. Such that when the design load is 100%, started from the critical section, 100% TL/AL is required, and when it is x%, then x% times TL/AL is required.
Case 1.
For vertical case such as wall,
the load design would often be as follows:

1. wind/ soil~ such that the design Moment would be  w*d/2(Design load)*d*2/3(Lifter arm) or w*d*d/2such that w*d^2/3 or w*d^2/2 at the section with distance 'd" form the top edge,

2. human impact load~ around 1KN at the top.

3.Vehicle impact load~ depends on the expected impact point from the top.

Say the wall is of  300 tk. and 50 cover. 
Then, start from the top just below the cover, the lap length would be 300-50*2=200
which would normally be enought for the design load. 
To fully understan the calculation, the load capacity at distance d below the cover would be
((200+d)/(Lap Length))*Design capacity for full TL/AL.
 
Case 2. and 3 is for the case when there is no support under the edge (Cantilever), and when the slab is constructed on a plane. (We would expect that poiint load or line load would be posed at the edge. So that a full anchorage is required. And, for easier to bend the edge U bar, we may minize the size of edge U bar if the design point or line load is enough. While according to the code (I have not confirmed), the smaller bar can only be one size smaller than the bigger bar. <<(Edited, present not well before***)

When the edge is under support (Regid joint), the TL/AL would be designed for the Moment at the top near supporting member. Which would not be discussed in this chapter

***What is the code principle based upon? Is the principle under the same design criteria?
 How about if I design it as "anchorage" to the slab?

4 comments:

Unknown said...

ASCE 7-10 Wind Load Calculation A very awesome blog post. We are really grateful for your blog post. You will find a lot of approaches after visiting your post.

Admin use said...
This comment has been removed by the author.
Admin use said...
This comment has been removed by the author.
Admin use said...

Last design concept in this writing refers to a female grad. E in this project. Cannot remember name clearly at that time, sorry

Post a Comment

waffle slab RC wall

原創 膠樽是很好的惰性物料,在無日曬下會十分耐用。 只要有工廠或機械自動裝沙機入膠樽, 那它可以當作為一定高度的檔土牆物料, 以減小石矢物料, 或,由於應該較少泥的特質, 所以作為擋土牆回填時的物料會減輕擋土牆的設計loading. 又或者室內批盪做間牆的...